  • Model: 5347A w/H05, C01, 011
  • Frequency Range: 10Hz to 20 GHz
  • Brand: HP
  • Number of Channels: 2
  • Power Range: -70 dBm to +20 dBm
  • Condition: This unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight. I am not 100% sure what option H05 is but it sounds like it is a military option, MATE for communications and C01 seems to have been a calibration option.
  • MPN: 5347A w/H05, C01, 011

    Description

    HP/Agilent 5347A 20 GHz Microwave Frequency Counter & Power Meters with Options: C01, H05, 011
    Comes with what you see in the pictures. If you don't see it, you probably won't get it.
    Specifications are from HP and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
    This unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight. I am not 100% sure what option H05 is but it sounds like it is a military option, MATE for communications.
    The Unit's Serial Number Tag Reads:
    Serial Number:
    3009A02625
    Option Information:
    C01:
    I believe this was a calibration option.
    H05:
    I couldn't find much information but from a third party that lists this is a Military MATE Communication option
    011:
    HP-IB Interface
    Description:
    The Keysight 5347A 20 GHz Microwave Counter/Power Meter offers the convenience of a single instrument that makes frequency and power measurements with accuracy and resolution comparable to stand-alone instruments. As a true power meter, the Keysight 5347A offers excellent dynamic range, linearity, and accuracy. It uses the same proven power sensors as HP's standalone power meters. The high-performance frequency counter measures frequency from 10 Hz to 20 GHz.
    With only five function keys, the Keysight 5347A is especially easy to use. Its rugged, lightweight package, along with an optional internal battery that provides up to two hours of cordless measurements, makes the Keysight 5347A ideal for taking portable measurements.
    True power meter performance
    Negligible power meter error
    Outstanding frequency measurements
    Built-in sensor calibration tables save time
    External DC operation for greater measurement flexibility
    Supports many HP power sensors
    Counter Specifications:
    Input 1:
    Frequency Range:
    500 MHz to 20.0 GHz
    Sensitivity:
    500 MHz to 12.4 GHz:
    -32 dBm (-35 dBm typical)
    12.4 GHz to 20 GHz:
    -27 dBm (-32 dBm typical)
    Maximum Input:
    +7 dBm
    Damage Level:
    +25 dBm, peak
    Connector:
    N(f)
    Coupling:
    AC
    Accuracy:
    ±LSD ±time base error x frequency. Accuracy specification applies from 0° to 50°C when using internal timebase, 0° to 55°C with external timebase.
    Resolution:
    1 Hz or 10 kHz, selectable
    Tracking Speed:
    Resolution = 1 Hz, speed = 1 MHz/s. Resolution = 10 kHz, speed = 1 GHz/s
    Acquisition Time:
    Resolution = 1 Hz, time = < 125 ms. Resolution = 10 kHz, time < 60 ms
    Maximum Deviation:
    20 MHz peak-to-peak, automatic mode
    Maximum FM Rate:
    10 MHz
    AM Tolerance:
    Any modulation index, provided the minimum signal level is not less than the sensitivity specification.
    External Timebase:
    10 MHz, 0.7 V min. to 8 V max peak-to-peak sine wave or square wave into > 1 KΩ shunted by < 30 pF, via front panel BNC connector.
    Input 2:
    Frequency Range:
    10 Hz to 525 MHz
    Sensitivity:
    25 mV rms (15 mV rms typical)
    Impedance:
    1 MΩ nominal shunted by < 70 pF (10 Hz to 80 MHz) or 50 Ω nominal (10 MHz to 525 MHz)
    Maximum Input:
    +10 dBm (50 Ω input), 1 V rms (1 MΩ input)
    Connector:
    BNC(f)
    Coupling:
    AC
    Resolution:
    1 Hz or 10 kHz, selectable
    Power Meter Specifications:
    Frequency Range:
    10 to 26.5 GHz, sensor-dependent
    Power Range:
    -70 dBm to +20 dBm (100 pW to 100 mW), sensor dependent
    Power Sensors:
    HP 8481A, HP 8481D, HP 8484A, HP 8485A (the HP 8481D is a direct replacement for the HP 84884A.)
    Dynamic Range:
    50 dB in 10 dB steps
    Display Units:
    Watts, dBm
    Resolution:
    0.01 dB in log mode, 0.1% of full scale in linear mode
    Accuracy:
    Instrumentation:
    ±0.02 dB or ±0.5%
    Zero Set (Digital Settability of Zero):
    ±0.5% of full scale on most sensitive range
    Power Reference:
    Power Output:
    1.00 mW. Factory set to ±0.7% traceable to U.S. National Institute of Standards and Technology.
    Accuracy:
    ±1.2% worst case (±0.9% RSS) for one year.
    General Specifications:
    Diagnostics:
    Rear panel or HP-IB selectable, service diagnostics and user information
    Data Output:
    Counter:
    Varies with frequency (90 measurements/sec with 10 kHz resol, DUMP mode)
    Power Meter:
    18 measurements/sec
    HP-IB Interface Functions:
    SH1, AH1, T5, L4, SR1, RL1, DC1, DT1, E1
    Operating Temperature:
    0° to 55°C
    Power Requirements:
    50 VA maximum
    Line Select:
    100 V (90 to 105 VAC rms; 47.5 to 440 Hz), 115/120 V (104 to 126 VAC rms; 47.5 to 440 Hz), 220 V (198 to 231 VAC rms; 47.5 to 66 Hz), 230/240 V (207 to 252 VAC rms; 47.5 to 66 Hz)
    External DC:
    14 to 26 VDC, 40 W, binding post
    Size:
    144 mm H x 325 mm W x 456 mm D (5.66" x 12.8" x 18.0")
    Weight:
    9.1 kg (20 lb)
    For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
    Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
    (1) Are you the end-user of this item?
    (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
    (3) What is the ultimate country destination?
    04/05/18